AGILE Series
Share
The Agile Series of inverters by Bonfiglioli sets new standards in technology for a broad range of users. Agile inverters are particularly suited for the food & beverage, textile, wood, packaging and ceramic industries, where they can be used in a variety of medium complexity automation processes.
Key features
- Series optionally extendable for field bus communication
- Sensorless control of synchronous and asynchronous motors
- Modbus and Systembus onboard
- DC link connection
- Integrated brake chopper
- Power failure control
- Programmable PI Controller
- Integrated VPLC
- Master/slave function with electronic gear
- Integrated safe torque off STO (SIL 2/ PL d) function
- Energy Saving function
- Intelligent current limits
- Output frequency 0...599 Hz, higher frequencies on request
- Diagnosis and setup via integrated keypad and integrated Service interface for PC connection
Specifications
Degree of protectionIP20 (EN 60529)Rated speed0 ... 599 HzCertificationsUL508c
STO (EN13849 / EN 61508)ConformityCE
EN61800
Specifications
- • Different Field bus options like CANopen, PROFIBUS, Modbus
• Optional accessories like brake resistor, mains chokes, mains filters
• Optional Connection set for connection to PC
Optional field bus communication:- CM-CAN: CANopen
- CM-PDP-V1: PROFIBUS
- CM232: Modbus ASCII & Modbus RTU for point-to-point connection
- CM485: Modbus ASCII & Modbus RTU via RS485 connection
- CM-DeviceNet: DeviceNet
- CM-EtherCAT®: EtherCAT®
- CM-PROFINET: PROFINET
- CM-Ethernet/IP: Ethernet/IP with one usable port as end-of-line device
- CM-Ethernet/IP-2P: Ethernet/IP with two usable ports (daisy chaining is possible)
- CM-Modbus/TCP: Modbus/TCP with one usable port as end-of-line device
- CM-Modbus/TCP-2P: Modbus/TCP with two usable ports (daisy chaining is possible)
- Ethernet VABus/TCP: VABus/TCP: with one usable port as end-of-line device
- Ethernet VABus/TCP-2P: VABus/TCP: with two usable ports (daisy chaining is possible)
Optional interface for communication to PC- ASK-USB: Communication to PC via optional communication cable
Optional PC software- VPlus for Windows operating system with motor setup, terminal monitor
- Actual value window, scope function, parameter storage
Accessories:- Brake resistors Type BR: The brake resistors offer an inexpensive solution to dissipate generator power that occurs at deceleration. A thermal sensor for the brake resistor protects the resistor from overheating.
- Power choke type LCVS & LCVT: Power choke types LCVS (for single-phase power installation) and LCVT (for three-phase power installation) increase the overvoltage protection of the inverter and increase the system's EMC.
- Power filters type FTV: Depending on the application boundaries, certain EMC levels must be achieved. The power filters are a component to improve EMC behavior in a machine installation.
- Power range (AGL402)
0.25 - 11 kW / three-phase 320 V... 530 V / 50 - 60 Hz (± 10%)
Power range (AGL202)
0.12 - 3 kW / single-phase 200 V... 240 V / 50 - 60 Hz (± 10%)
0.25 - 7.5 kW / three-phase 200 V ... 240 V / 50 - 60 Hz (± 10%)
- Integrated Keypad
- Integrated brake chopper
- Integrated Safe Torque Off function
- DC link connection
- 6 digital inputs, 2 multifunction A/D inputs
- 1 digital output, 1 multifunction I/O
- 1 relay output, 1 multifunction A/D/Pulse output
- Signal supply outputs: +24 V DC, + 10 V DC
+24 V DC input for electronic power supply
- Serial interfaces: RS-232, RS-485 including Modbus support
system bus
- Preset values for Bonfiglioli motors to decrease commissioning times
- Flexible assignment of digital inputs and outputs
- Energy Saving function
- Ready to use application macros
- Motor chopper function to increase braking power without brake resistors
- Power failure regulation
- Fault history
- Motor and inverter state memory
- Integrated PLC function with graphic development environment
• AGL202: 0.12 - 3 kW / single-phase 200 V... 240 V / 50 - 60 Hz (± 10%) 0.25 - 7.5 kW / three-phase 200 V ...240 V / 50 - 60 Hz (± 10%)
• AGL402: 0.25 - 11 kW / three-phase 320 V... 530 V / 50 - 60 Hz (± 10%)
• Cabinet mounting for all sizes
• Optional feed-through mounting
• Optional DIN rail mounting frame
- Motor compatibility
- Two types of motors:
- Asynchronous AC motors
- Permanent magnet synchronous (brushless) motors
Motor Control(open loop):
• Asynchronous AC motors
• Permanent magnet synchronous (brushless) motors
Types & Powers
Type kW (three-phase) AGL402-02 1 0.25 AGL402-03 1 0.37 AGL402-05 1 0.55
Type kW (three-phase) AGL402-07 1 0.75 AGL402-09 1 1.1 AGL402-11 1 1.5 AGL402-13 1 2.2 AGL402-15 2 3.0 AGL402-18 2 4.0 AGL402-19 2 5.5 AGL402-21 2 7.5 AGL402-19 3 5.5 AGL402-21 3 7.5 AGL402-22 3 9.2 AGL402-23 3 11
Type kW (three-phase) AGL202-02 1 0.25 AGL202-03 1 0.37 AGL202-05 1 0.55 AGL202-07 1 0.75 AGL202-09 1 1.1 AGL202-11 1 1.5 AGL202-13 1 2.2 AGL202-15 2 3.0 AGL202-18 2 4.0 AGL202-19 3 5.5 AGL202-21 3 7.5
Type kW (single-phase) AGL202-02 1 0.12 AGL202-03 1 0.18 AGL202-05 1 0.25 AGL202-07 1 0.37 AGL202-09 1 0.55 AGL202-11 1 0.75 AGL202-13 1 1.1 AGL202-15 2 1.5 AGL202-18 2 2.2 AGL202-19 3 3 AGL202-21 3 3